The BCI50ES test bench performs filter tests in compliance with the UNI EN 13443:1 - 7.2 - 7.3 - 7.4 standards.
TECHNICAL DATA:
• Maximum operating pressure 50 bar
• Minimum operating pressure 5 bar aprox.
• Maximum compressible volume between 0 and 15 dm3
• Test frequency ≥ 0,25 Hz
• Operating oil temperature 50° C
• Operating water temperature between 5 and 35°C
• The bench can work 24h per day with automatic alarm and shutdown system in case of any malfunction
• Stainless stell testing chamber (it can be modified upon request)
SAFETY DEVICES:
• Interlocks, which prevent from starting the test when the hatch is open
• Openings to display the elements being tested, provided with protective glasses
• Emergency button
• Automatic interruption in case of any bench malfunction
POWER SUPPLY:
• Standard voltage: 400V - 50 Hz - 3Ph (special voltages available upon request)
• Total installed power 3,7 kW
OPTIONAL:
• Failure detection sotfware and online remote support
• Industrial PC with 17'' touch-screen display on mobile support
OP S.r.l. - Via del serpente, 97 - 25131 Brescia BS (Italy) - Registro Imprese Brescia / CF: 01284460175 - VAT NUMBER: 03244960179 REA BS 257920 Share capital Euro 102,960.00 fully paid