The BCP350AIRES test bench performs leak tests on heat exchangers using a dedicated pneumatic circuit capable of generating a test cycle with a controlled pressure rate.
TECHNICAL DATA:
• Maximum testing pressure of 350 bar (5075 Psi).
• Maximum heat exchanger size 1000x2500 mm.
• Maximum heat exchanger volume 30 lt.
• Accurate pressure regulation +/- 3 bar.
• Possibility to execute pressure ramps with different gradients
SAFETY DEVICES:
• Electric interlock of testing if the door is open
• Emergency stop button
• Automatic shutdown in the event of any malfunction
• Testing chamber fully lined with absorbent material
• Pressurized gas dispersion system through anti-expulsion deflectors
POWER SUPPLY:
• Standard voltage 400 V – 50 Hz – 3Ph (special voltage upon request)
OPTIONAL
• Additional anti-burst protection
• Extra wide test chamber
• Online remote support – software for diagnostics and remote assistance
• Mobile control panel
• High-pressure compressor
• Adapter sets